Permanent measurement and monitoring of particles
The MACView® Particles is a monitoring system for particles like dust and smoke. It is specially developed for use in work rooms and industrial environments. The MACView® Particles measures, reproduces data, registers data using software and controls an external alarm, if needed. The principle of measurement is based on the principle of diffusion of infrared light.
Displaying, alarming and registering
The MACView® Particles displays the measured values on an LCD-display in mg/m3 (milligramme per cubic metre). The value can be compared to the MAC-value (Maximum Allowable Concentration) directly.
In the monitoring system, 2 relais and 1 analog output are built-in which can be used to trigger an external alarm- or ventilation installation. It is possible to activate an acoustical or visual alarm to make people aware of too high concentrations.
With the optional software (useable for Windows), data can be saved, printed and graphical represented remotely. The data can be exported to every desired format to be used in own files. In the software, the MAC-values of the various kinds of dusts are adjustable seprately. It is also possible to set up for multiple dusts. The program will send the correct average MAC-value to the MACView® Particles.
Material of Housing | aluminium | |
Approval | CE | |
Protection classification read-out unit | IP65 | |
Dimensions | 61 x 116 x 189 mm | |
Sensor Diameter | 130 mm | |
Warming-up time | 240 sec. | |
Short-term Stability | ± 3% | |
Long-term Stability | ± 5% | |
Signaling / Alarming | mg/m3 en hysterese configurable | |
Display specifications | using back-lit LCD display with 2 rows x 16 characters | |
Unit MAC value on display | parts per million (ppm) | |
Measurement Range | up to 16 mg/m3 | |
Acceptance of Alarm | by use of reset pushbutton | |
Communication with pc | via an RS232-cable | |
Outputs | - 2 relaisoutputs (up to 250 VAC switchable separately) - 1 analoge output 0-10 V or 4-20 mA (at choice) | |
Speed of the microcontroller | up to 20MHz | |
Fastening | Read-out unit and sensor can be fastened to the wall together or apart easily. | |
Software | The MACregister® software is useable for Windows 95, 98, ME, NT, 2000 and Windows XP. |
- Application note MacView Particles
- Getting started guide and operating manual
- Leaflet MacView Particles Advanced
- Leaflet MacView Particles
- Operation principle particles sensor standard
- Application note MACView-Particles (English)
- Intelligent sensors control the air quality on the workplace (English)
- Leaflet MACView-Particles (English)
- Operation principle particles sensor (English)
- Gebruiksaanwijzing_Particles-NL (Dutch)